ELECTRONICS (Basel), cilt.15, sa.8, ss.1-33, 2026 (SCI-Expanded, Scopus)
In three-phase PWM rectifiers, abrupt load changes and parameter variations challenge DC-bus voltage regulation and degrade the performance of conventional controllers. To ensure robust regulation under nonlinear and time-varying conditions, this study proposes a type-3 fuzzy logic controller (T3-FLC) for DC-bus voltage regulation. The T3-FLC enhances the conventional type-1 framework by employing a three-dimensional membership structure that captures both vertical and horizontal uncertainties in the fuzzy inference process. This structure improves adaptability and stability in the face of system disturbances. The proposed controller was compared with a conventional proportional-integral (PI) controller and a type-1 fuzzy logic controller (T1-FLC) under different operating conditions: constant reference, reference tracking, load variation, regenerative operation, and grid disturbances. Under reference tracking mode, it settles within approximately 12 ms for the largest reference step, with the overshoot kept below 0.3%, whereas the T1-FLC and PI controllers require noticeably longer settling times and exhibit higher overshoot. In regenerative operation, the T3-FLC maintains tight DC-bus regulation with recovery times of 10–12 ms and an overshoot of about 2.7%, outperforming the benchmark controllers. Power quality analysis further shows that the proposed controller maintains low input-current distortion, with THD approximately 5–13%, and a near-unity power factor across all scenarios. These results confirm the T3-FLC as an effective control strategy for power converters.