Simulation of LYSO Crystal for the TAC-PF Electromagnetic Calorimeter
ACTA PHYSICA POLONICA A, sa.3, ss.527-529, 2017 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Basım Tarihi: 2017
- Doi Numarası: 10.12693/aphyspola.131.527
- Dergi Adı: ACTA PHYSICA POLONICA A
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
- Sayfa Sayıları: ss.527-529
- Anahtar Kelimeler: 29.40.Mc, 02.70.Uu, HIGH-ENERGY-PHYSICS, LARGE-SIZE LSO, DAMAGE, BELLE
- Bursa Uludağ Üniversitesi Adresli: Evet
Özet
In addition to PWO and CsI(Tl) crystals, cerium doped LYSO crystal is considered for the electromagnetic calorimeter part of the Turkish Accelerator Center Particle Factory (TAC-PF) detector, because of its high light yield, fast decay time and good radiation hardness. In this work, LYSO crystals arranged in 3 x 3 and 5 x 5 matrices have been simulated against photons in the energy range between 50 MeV and 2 GeV, using Geant4 simulation code. Energy resolutions have been estimated considering the contribution of photoelectron statistics coming from the avalanche and PIN photodiodes.