Time-dependent changes in gingival crevicular fluid volume during orthodontic tooth movement with clear aligners and fixed appliances


TOSUN BALCI İ., NALBANTOĞLU A. M., ALBAYRAK E., BİNGÖL D.

CLINICAL ORAL INVESTIGATIONS, cilt.30, sa.12, 2026 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 30 Sayı: 12
  • Basım Tarihi: 2026
  • Doi Numarası: 10.1007/s00784-026-07261-4
  • Dergi Adı: CLINICAL ORAL INVESTIGATIONS
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, EMBASE, MEDLINE, Academic Search Ultimate (EBSCO), Natural Science Collection (ProQuest), Biological Science Database (ProQuest), Biomedical Reference Collection: Corporate Edition (EBSCO), Health Research Premium Collection (ProQuest), Pharma Collection (ProQuest)
  • Bursa Uludağ Üniversitesi Adresli: Evet

Özet

Objectives This study aimed to evaluate temporal changes in gingival crevicular fluid (GCF) volume during orthodontic treatment with clear aligners and fixed appliances. Materials and Methods Thirty-two patients were included in this prospective study (clear aligner group, n = 17; fixed appliance group, n = 15). GCF was collected from the buccal site of tooth 12 and the palatal site of tooth 16 at five time points: baseline (T0), 1 h (T1), 1 day (T2), 1 week (T3), and 1 month (T4). GCF volume was measured using a Periotron. Intergroup comparisons were performed using independent samples t-tests, and temporal changes using a repeated measures general linear model. Results At tooth 12, no significant intergroup differences occurred at T0-T3, whereas the fixed appliance group showed significantly higher values at T4 (p = 0.003). At tooth 16, the clear aligner group showed higher values at T1 (p = 0.043), with no differences at other time points. Repeated measures analysis revealed a significant time effect (p < 0.001) with a non-linear pattern. Conclusions GCF volume showed time-dependent, non-linear fluctuations during orthodontic treatment. Although the overall group effect was not significant, a significant time & times; group interaction and isolated differences at tooth 16 at T1 and tooth 12 at T4 suggest that the temporal pattern, rather than overall magnitude, of GCF volume change may differ between orthodontic systems, potentially reflecting differences in local vascular and crevicular fluid dynamics. These findings provide a preliminary temporal framework rather than evidence of distinct underlying biological mechanisms.