Experimental ion mobility measurements in Ne-CF4


Marques D. J. G., Cortez A. F., Escada J., Veenhof R., Neves P. N. B., Conde C. A. N., ...Daha Fazla

JOURNAL OF INSTRUMENTATION, cilt.14, 2019 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 14
  • Basım Tarihi: 2019
  • Doi Numarası: 10.1088/1748-0221/14/04/p04015
  • Dergi Adı: JOURNAL OF INSTRUMENTATION
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Bursa Uludağ Üniversitesi Adresli: Hayır

Özet

In this paper we present the results of the ion mobility measurements made in gaseous mixtures of neon with carbon tetrafluoride (Ne-CF4) at a total pressure 8 Torr (10.6 mbar) and for low reduced electric fields in the 10 to 25 Td range (2.4-6.1 kV.cm(-1).bar(-1)), at room temperature. The time-of-arrival spectra revealed only one peak, which was attributed to CF3+. The reduced mobilities obtained from the peak centroid of the time-of-arrival spectra are presented for Ne concentrations in the 5%-95% range.