JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, cilt.25, ss.1809-1816, 2022 (ESCI)
A domestic solar water heating system using a flat plate collector is modeled for the domestic hot water requirement of a residential unit in Ankara, Turkey. The necessary design parameters were determined and the analysis was carried out using the TRNSYS simulation program. In the modeled system, the domestic water temperature was determined as 55 degrees C and water withdrawals were carried out at different flow rates during the day according to the usage intensity. The water withdrawal rates were determined as 80 kg/h between 07.00-09.00, 100 kg/h between 12.00-13.00 and 50 kg/h between 17.00-22.00. According to the results obtained, the designed system was able to meet the hot water need in summer and winter months by using solar energy through auxiliary heaters. While the collector efficiency reached its highest value with 40% in September, it reached the lowest efficiency value with 8% in December.